EUROTRON UniGas 1000 COMBUSTION GAS ANALYSER

  Compact and ergonomic, fits in your hand. Easy to use with large multiline display. Ambient CO safety monitoring.

  Proprietary design water trap. Draft & differential pressure meter. Low cost tool for boiler maintenance.

 

 

 

  Display : LCD display 40 x 58 mm with backlight device

  Sensors : O2, CO, CO2

  Smoke index

  Easy replaceable gas sensors

  Pressure / Draft input

  Infrared port : compatible with HP82240B cordless printer

  Self-diagnosis : sensors efficiency test / display diagnostic messages

  Calibration : automatc, at instrument switch-On

  Printer : built-in impact

  Printer report header : 4 programmable lines  

  Printer power supply : from the analyser battery pack

  Operating temperature : -50°C to +450°C

  Storage temperature : -20°C to +60°C

  Power supply : high capacity Ni-MH rechargeable battery pack/external battery charger

  Charging time : 8 hours at 90 % with instrument Off

  Battery life : 6 hours (typical) continuous use (without printing and backlight)

  Dimensions : 115 x 90 x 330 mm

  Weight : 1,1 kg with battery and printer

Easy replaceable gas sensors UniGas 1000 uses long life low maintenance sensors for O2 and CO.

Standard Report of Calibration Each instrument is factory calibrated and certified against Eurotron Standard to ensure traceability, and shipped with a Report of Calibration.

Rechargeable battery operations Ni-MH rechargeable batteries provide longer field use. Flue gas analyser and internal printer is powered by unique batteries. Charger is supplied as standard.

Built-in impact printer The instrument is available with or withhout a built-in rugged impact printer. Certainly more readable, long time and heat resistant than the thermal printout on chemical paper.

Pressure / Draft input Differential pressure input to verify : draft, gas pipework leak with pressure decay programme, gas vflow pressure, pressure in combustion chamber, ΔP on filters and fan, pressure switches calib ration.

Smoke index measurement is performed by using the optional external hand pump. The results can be stored in the internal memory and printed on the report.

Ambient CO safety monitoring A procedure can be selected to monitor the CO in ambient air using the internal sensors. An internal program allows the CO max measurement in atmospheric boiler check.

Parameters

O2 : 0 - 25 %

CO : 0 - 4000 ppm

CO2: 0 - 99,9 %

Temp. air : Pt100; -10 - 100°C

Pressure/Draft : -10 hPA to 100 hPa

Excess air : 1,00 - infinity

Efficiency : 1 - 99,9%

 

Standard package

Unigas 1000 basic unit

Battery charger

Differential pressure sensor

Infrared port for HP thermal printer

Rubber holster

Instruction manual

Eurotron calibration certificate